Version Differences for OPH1004

Line 100:
  ==Application Development==    ==Application Development== 
  The OPH1004 firmware is split into two levels, an Operating System and an Application. The Operating System Exposes the functions of the hardware to the Application level firmware, and the Application determines how the device behaves. The Operating System is developed and maintained solely by Opticon, however anyone can make an application for the OPH1004 using using Opticon's C-Library Kit and the included GCC WinArm Compiler.     The OPH1004 firmware is split into two levels, an Operating System and an Application. The Operating System Exposes the functions of the hardware to the Application level firmware, and the Application determines how the device behaves. The Operating System is developed and maintained solely by Opticon, however anyone can make an application for the OPH1004 using using Opticon's C-Library Kit and the included GCC WinArm Compiler.  
    + ===Development Tool SpeedGen===  
    + SpeedGen utilizes an interpreter application and a configuration file called a build file to rapidly customize the appearance flow and operation of an OPH1004 data collector. It allows you to tailor your application for your particular workflow. SpeedGen applications consist of screens, each containing data fields, which users fill in by either scanning barcodes, keying data, or a combination of the two. Each data field can also validate user input from one of three data files which are uploaded to the Opticon device.  
    + ====Getting Started with SpeedGen====  
    + To use Speedgen:  
    + # You must install the Speedgen program on your computer.  
    + # Then install the Speedgen interpreter application on your Opticon data collector.  
    + # Once you have done this you can use Speedgen to configure a build file  
    + # And finally use Speedgen to transfer that build file to the device.  
    + # Now you have an application custom tailored for your needs.  
       
    + ====Help?====  
    + This version of Speedgen comes with a detailed help file rather than a manual. So if you get stuck trying to figure out how to configure your build file then please consult the help file. If you have a specific question or would like some general guidance you are always welcome to write Opticon Technical Support. We can't make the application for you but we are always willing to help.  
       
  ==Downloads==    ==Downloads== 
       
Line 139:
  | Firmware: Application - USA Standard Demo || This is the standard application running on all OPH1004s from our warehouse. It supports a large variety of barcode symbologies (which ones are configurable). Data is stored as a database including the barcode data scanned, the number of times that barcode has been scanned (with optional user quantity input) and the date and time the last entry was updated). Note that when data is viewed on the PC there is significant white space after the barcode data before you will see the quantity and time stamp information due to the nature of the database schema. It would be necessary to scroll to the right to see this extra information. || [http://ftp.opticonusa.com/Downloads/OPH1004%20Firmware%20-%20Application%20XFC3092x.zip Download]    | Firmware: Application - USA Standard Demo || This is the standard application running on all OPH1004s from our warehouse. It supports a large variety of barcode symbologies (which ones are configurable). Data is stored as a database including the barcode data scanned, the number of times that barcode has been scanned (with optional user quantity input) and the date and time the last entry was updated). Note that when data is viewed on the PC there is significant white space after the barcode data before you will see the quantity and time stamp information due to the nature of the database schema. It would be necessary to scroll to the right to see this extra information. || [http://ftp.opticonusa.com/Downloads/OPH1004%20Firmware%20-%20Application%20XFC3092x.zip Download] 
  |-    |- 
- | Firmware: Application - [[SpeedGen]] Application Interpreter || This application must be loaded prior to loading any [[SpeedGen]]-created files onto the terminal. || [ftp://ftp.opticonusa.com/pub/Downloads/OPH1004_SpeedGen_Interpreter_XFC35694.zip Download ]   + | Firmware: Application - [[SpeedGen]] Application Interpreter || This application must be loaded prior to loading any [[SpeedGen]]-created files onto the terminal. || [http://ftp.opticonusa.com/SpeedGen/OPH1004_H13/SpeedGen%20EGF35691.exe Download ]  
  |}    |}