H-25

About

Rugged Windows CE 6.0 Terminal

The H25, a power-packed Windows CE 6.0 mobile device from Opticon, offers a rugged, yet lightweight, compact design that is ideal for today’s mobile workers in field sales and service, inventory control, asset management, security and inspections and merchandising. H25 product highlights include:

Tech Specs

Features and Benefits

Basic Product Specifications

Operation

Memory

Display

'Operating indicators

Operating keys

Communication

Power

Camera

Barcode scanner Optics (1D laser option only)

2D Imager optics (2D imager option only)

Supported Symbologies (1D imager option only)

Supported Symbologies (2D imager option only)

Durability

Physical

Regulatory & Safety

Accessories

Enclosed items

Sold separately

How to:

Configure Ethernet Cradle Options

To use the optional Ethernet Cradle interface and enable Windows File Sharing we should first configure user accounts and the device name using the web interface. To do this, first connect your Ethernet cradle both to power using the supplied power adapter, and to an active Ethernet port on your local network using an Ethernet patch cable.

Remote Device Administration

To remotely manage the device, open up a web browser on a local computer, and navigate to the device using its IP address. For example, to navigate to the H25 with Ethernet IP address 172.30.101.90, open up Internet Explorer or your web browser of choice, and enter "http://172.30.101.90/" then press Enter.

If you have not previously set an Admin password for the device, the first page that you will see will prompt you to set one. Please choose a secure password, and enter it twice. The interface will restart, and after 30 seconds will present you with the Windows CE Remote Management Tool.

Device Management Device Management presents two options:

Security Security presents one option, which allows you to reset the Admin password to something new.

Add/Del Users This page allows you to add additional users to your CE device. Each user can be given access to their own shares on the device, allowing you to for example give different services or users remote access to different files without having to use the device administrative password.

File Server and Printer This page contains some very useful capabilities, and gives you the ability to configure remote Windows Shares from which you can download data off the device.

Browsing the Device Remotely

To browse the device remotely, first set up a file share using the remote management webpage(see previous section). Once you've set up your share, open up File Explorer on a Windows PC, then navigate to your terminal like you would a file server. For example, if my terminal's IP address is 172.30.101.98, then I can browse its shares by entering \\172.30.101.98\ into File Explorer in Windows.

Once you've attempted to browse to the terminal, you will then have to enter your username and password to connect to individual shares.

Find the IP address

To find the IP address of the device, navigate to Start->Settings->Network & Dial-up. The IP address for the Ethernet interface will be available on the AX88772B network connection, while the IP address for the wireless interface will be available on the SDCS30AG interface.

Performing a Warm Boot ( Soft Reset ) on the H25

To perform a Warm Boot on the H25, press and hold the following keys at the same time: "Fn"+"ALPHA"+"Enter". Then release the buttons. A Warm Boot will not delete any data or erase settings.

Performing a Cold Boot ( Hard Reset ) on the H25

To perform a Cold Boot on the H25, press and hold for 3 seconds the following keys at the same time: "Fn"+"Enter"+"Power Button". The device should now perform a Cold Boot.

WARNING: A cold boot resets the device into factory default settings. All data that is not in the DiskOnChip folder of the device, will be deleted.

Perform a Backup on the H25

To Backup your data, go to Start -> Settings -> Backup/Restore utility. Select the place where you you want to save your data in the Target/Source menu. Then press Backup button: can take a minute to Backup your data.

Restore a Backup on the H25

To restore a previously performed backup of your data, go to Start -> Settings -> Backup/Restore utility. Select the place where you previously have saved your data from the "Restore from" menu. Then press Restore button: your data will be restored.

Restoring automatically from a Backup on the H25

Downloads

Notice: The downloading and use of any Opticon software implies consent with Opticon's End User License Agreement.

Documents

Document Description Version Download
User Manual This is the User Manual for the H25. 1.1 Download
Datasheet This is the datasheet for the H25. 101514 Download
Quick Start Guide This is the quick start guide that comes in the box with the H25. Download

Software

Software Description Version Download
Scan Engine Firmware Upgrade Utility This application can be used to update the MDI or MDL firmware on an H25. Download
H25 SDK The H25 SDK. Contains the necessary C++ header file, dotNET dll, documentation and sample code (for dotNET) Download



Categories: Mobile Solutions  | Windows CE