About

The OPL9724 is a wireless 1D terminal scanner. It runs a low-level firmware, typically called the "OS", and on top of that runs an application, which essentially drives the behavior of the device and exposes a simple user interface on the OPL9724's LCD screen. The application can be customized in order to change the behavior of the OPL9274, using Opticon's C-Library Kit and the Toshiba C Compiler. This allows end-users to create custom applications modeled around their barcode-driven processes, making the OPL9724 a simple and flexible solution for many business needs.

The OPL9724 is used in combination with a cradle (typically CRD9723) in order to charge the OPL9724's removable battery, transfer data serially to a host (using plain ASCII, XModem, or Opticon's NetO), and load new OS revisions and applications (using Opticon's Appload). Other types of cradles exist, including a dialup modem cradle and a GSM cradle, which OPL9724 applications can utilize with Opticon's TCP/IP Library.


Downloads


Notice
The downloading and use of any Opticon software implies consent with Opticon's End User License Agreement.

Documents

Document Description Download
User Manual: Application LFBP0511 This is the User Manual for the behavior of the device while it is running the USA Standard Demo (pre-loaded from our warehouse on all OPL9724 units). Download
Universal Menu Book This document contains all of Opticon's standard configuration barcodes. The ability to configure the OPL9724 terminal with this commands manual is application dependent (not supported on any of the Standard Demos). Download


Software

Software Description Download
Appload Appload is Opticon's multi-purpose utility for installing firmware onto devices such as the OPL9724. Currently Windows only. Download
NetO32 NetO32 is an application that is used to download data from a few of Opticon's devices. Data is downloaded in whole file format exactly as it is stored on the device it is being uploaded from. Download
Firmware: OS This is the latest Operating System firmware file for the OPL-9724. Download
Firmware: Application - USA Standard Demo This is the standard application running on all OPL9724s from our warehouse. It supports a large variety of barcode symbologies (which ones are configurable). Data is stored as a database including the barcode data scanned, the number of times that barcode has been scanned (with optional user quantity input) and the date and time the last entry was updated). Note that when data is viewed on the PC there is significant white space after the barcode data before you will see the quantity and time stamp information due to the nature of the database schema. It would be necessary to scroll to the right to see this extra information. Download


Drivers

Platform Description Download
All In One Installer Package USB-to-serial drivers installer package for both 32 and 64 bit versions of Windows XP (32 bit only), Vista, and 7. This package contains two drivers. The first driver is for the OPN-200x as well as many of Opticon's other products. The second driver is for Opticon's cradles and a few other products. You can choose any of the drivers to install on the first screen of the installer program. Download

Loading Firmware

The OPL-9724 is basically a mini computer. As such it has an Operating System and runs Applications (one at a time, loding one application erases the previous one). The process for loading either the OS or an Application file is the same for both and so the instructions for either are combined here. Opticon always provides updates to the OS (see the Downloads table above). Opticon also provides free Applications for use on the OPL-9724 though it is also common for independent software vendors or resellers to develop their own software for use on the OPL-9724 (this is especially true if the company also provides PC side software). Applications made by Opticon are available at the Downloads table above (with the exception of software made custom by contract which is provided in other ways to the purchaser). Applications made by a third party must be retrieved from said party.

Download Files

You will need a few files to update your OPL-9724. All of these files can be found in the Downloads table above.

  • USB Cradle Drivers
  • Firmware: OS
  • Firmware: Application
  • Appload

Set Up Your Cradle

It is likely that you are using your OPL-9724 in conjunction with the cradle CRD-9723. For instructions setting this up including installing Drivers see here.

Install and Configure Appload

Appload is a PC application that we use to load firmware on most of Opticon's devices. Once it is installed (by running the installer found in the Downloads table above) it will launch automatically. Change the options 'Settings' > 'Port' to match the COM port of either the USB or RS232 interface (whichever was used). You may also need to change 'Settings' > 'IrDA Adapter/cradle type' to be 'Not Installed'.

Load the Firmware

Now that the cradle is configured, Appload is installed and configured you need to simply place the unit on the cradle then select 'File' > 'Download' from the Appload menu and browse to the firmware file you wish to load. Note that if you must upgrade the OS as well as an Application you will need to follow this step twice.

Download Data

All of Opticon's Demo Applications for the OPL9724 support downloading of data through Opticon's proprietary protocol called NetO (Net-Oh). As with all communications there are two sides. In this case these are the terminal (the OPL9724) and the host (usually a PC). This section covers setting up and using such a communication channel.

Setting Up the Host

To use NetO communications on a PC you need an application called NetO32. This can be downloaded from the Downloads table above on this page. Simply run the installer after download is complete and follow the setup instructions here.

  • Select 'Tools' > 'Options'
    • Choose RS232 from the menu at left
      • Choose the COM port for your cradle (COM 1 if using RS232, check Device Manager for USB ['Start' > 'Run' > 'devmgmt.msc' > click 'OK' and look under the 'Ports' section])
      • Change Baudrate to 115200
      • Change IrDA Device to 'None'
    • Choose 'Download' from the menu at left
      • Click the 'browse' folder icon at right to change the destination folder of the file once you have downloaded it.
      • Choose between 'Append', 'Overwrite', and 'Unique' to determine what happens when you download a data file but a file by that same name is already present.
    • Click 'OK'
  • Select 'File' > 'Save As'
    • Choose a file name appropriate for you (such as your name or your company's name) to save the settings you just changed.
    • Now every time after this that you open NetO32 you must select 'File' > 'Open' and choose this file to load your settings.
  • Select 'Protocol' > 'Start'

NetO32 is now in 'Polling' mode. Note that you should see the yellow light on the cradle blinking steadily. This means it will sit here indefinitely sending queries to the cradle and waiting for the right response to start a download. Multiple downloads can all be done without ever closing NetO32. When you are done using NetO32 simply select 'Protocol' > 'Stop' and NetO32 will discontinue polling mode. The application can then be closed.