Version Differences for XLB1000 OK/NG

Line 1:
    + Interface OK/NG  
       
    + The technical information about the OK and NG (no good) signals for the NLB-1000 and the NVL-1001 can be found on this page  
    + Contents  
    + [hide]  
       
    + 1 Technical details  
    + 1.1 OK/NG sequencer test results for the NLB-1000 (motor on when idle)  
    + 1.2 OK/NG sequencer test results for the NLV-1001 (motor on when idle)  
    + 2 OK NG sginal menu options  
       
    + Technical details  
    + OK/NG sequencer test results for the NLB-1000 (motor on when idle)  
       
    + File:NLB-1000.JPG  
       
    + Note 1: The trigger-to-decode time of 2,6 to 3,8 ms when the motor is ON when idle is respectively 250ms – 275ms when the motor is OFF when idle  
       
    + Note 2: To test the performance, always present a barcode of high quality at a fixed distance. Before starting the test, make sure that the barcode is read 1000 times per second by performing a read test in the laser adjustment mode.  
       
       
       
    + OK/NG sequencer test results for the NLV-1001 (motor on when idle)  
       
    + File:NLV-1001.JPG  
       
       
    + Note 1: The trigger-to-decode time of 45 to 64 ms when the motor is ON when idle is respectively 91ms – 95ms when the motor is OFF when idle  
       
    + Note 2: To test the performance, always present a barcode of high quality at a fixed distance. Before starting the test, make sure that the barcode is read 100 times per second by performing a read test in the laser adjustment mode.  
    + OK NG sginal menu options  
       
    + Use this menu code sheet to adjust the settings on the scanner  
       
    + File:OK_NG_signal_menu_options.JPG Interface OK/NG signals  
    + Category: Interface