Version Differences for PHL2700

(Software)
(Application Loading)
Line 9:
       
  ==Application Loading==    ==Application Loading== 
- *Cradle baud rate must be set to 19200 (Dip switches::1 ON, 2 OFF, 3 OFF, 4 OFF 5 OFF 6 ON)   + The standard demo application can be loaded either through the IRU-2700 cradle, or through the direct load cable for the PHL-2700. The process differs depending on which method you choose to use.  
- *With device powered off press [0] + [7] + [PW] - this enters the system menu      
- *Scroll to 'Download Appl' and press [ENT]   + ===Through the Direct Load Cable===  
- *Scroll to 'Via cradle' and press [ENT]   + *Before you begin, make sure that the batteries in the unit are charged to ensure that the unit does not power off during application loading.  
- *Appload IrDA Adapter/Cradle type must be set to 'Tekram compatible'   + *Download and install [[Appload]] onto a PC running Windows, and download the USA Standard Demo Application. These will both need to be available in order to load the Application.  
- *Drag and drop Application file (i.e. CFW20230.S2)   + *With the device powered off, hold [0] and [7], and then press [PW] to enter the System Menu.  
    + *From the System Menu, select "Download appl," then choose "Via Cable."  
    + *Start [[Appload]] on your PC, and in the Settings menu, change the IrDA Adapter/Cradle type to "No Cradle," and choose the correct COM port for the PHL-2700.  
    + *Extract the file in the USA Standard Demo Application download from above, and drag and drop that file onto the Appload window to start the download. If everything is working, the PHL and Appload will show a percentage to indicate the progress of the download.  
       
    + ===Through the IRU-2700 Cradle===  
    + *Before beginning, the cradle's baud rate must be set to 19200 (Dip switches::1 ON, 2 OFF, 3 OFF, 4 OFF 5 OFF 6 ON). The Dip switches are located under a plastic cover on the bottom of the cradle.  
    + *Download and install [[Appload]] onto a PC running Windows, and download the USA Standard Demo Application. These will both need to be available in order to load the Application.  
    + *With the device powered off, hold [0] and [7], and then press [PW] to enter the System Menu.  
    + *From the System Menu, select "Download appl," then choose "Via Cradle."  
    + *Start [[Appload]] on your PC, and in the Settings menu, change the IrDA Adapter/Cradle type to "No Cradle," and choose the correct COM port for the PHL-2700.  
    + *Extract the file in the USA Standard Demo Application download from above, and drag and drop that file onto the Appload window to start the download. If everything is working, the PHL and Appload will show a percentage to indicate the progress of the download.  
       
  ==Diagnostic Tool==    ==Diagnostic Tool==