Line 3: |
|
|
|
|
|
The OPL9728 is used in combination with a cradle (typically [[CRD9723]]) in order to charge the OPL9728's removable battery, transfer data serially to a host (using plain ASCII, XModem, or Opticon's [[NetO]]), and load new OS revisions and applications (using Opticon's [[Appload]]). Other types of cradles exist, including a dialup modem cradle and a GSM cradle, which OPL9728 applications can utilize with Opticon's [[TCP/IP Library]]. |
|
The OPL9728 is used in combination with a cradle (typically [[CRD9723]]) in order to charge the OPL9728's removable battery, transfer data serially to a host (using plain ASCII, XModem, or Opticon's [[NetO]]), and load new OS revisions and applications (using Opticon's [[Appload]]). Other types of cradles exist, including a dialup modem cradle and a GSM cradle, which OPL9728 applications can utilize with Opticon's [[TCP/IP Library]]. |
|
|
|
|
|
|
+ |
==How to install the demo application and then download data to a PC==
|
|
|
|
|
|
|
+ |
To connect OPL-9728 to PC you need to have a cradle. If your cradle has USB interface, download the USB driver from the following link: http://www.opticon.com/uploads/Software/CRDX72Xusbdriver.zip
|
|
|
|
|
|
|
+ |
Also to load the demo application on to your scanner you need Appload. Appload can be downloaded here:
|
|
|
+ |
http://www.opticon.com/uploads/Software/EAGAPPLOAD.zip
|
|
|
|
|
|
|
+ |
To load the demo application follow these steps:
|
|
|
|
|
|
|
+ |
:# Run Appload and go to setting->port and select com port. (If your cradle has RS232 select COM1, if your cradle is connected to PC via USB you need to find out which com port is assigned for your device. To find COM number go to start->control panel->system->hardware->device manager->under ports you can find COM port number)
|
|
|
+ |
:# From Appload go to setting->IrDa Adaptor/Cradle type and select not installed.
|
|
|
+ |
:# From OPL-9728 press and hold all three blue buttons under the LCD simultaneously to go to the OS system menu
|
|
|
+ |
:# Select download application
|
|
|
+ |
:# Put your scanner into the cradle
|
|
|
+ |
:# Now drag and drop the demo application that you downloaded earlier on to the Appload window.
|
|
|
+ |
Appload will now automatically load the demo application onto the scanner.
|
|
|
|
|
|
|
+ |
To download data from scanner into PC following steps must be taken:
|
|
|
|
|
|
|
+ |
Download "Neto32" from the following link:
|
|
|
+ |
http://www.opticon.com/Software-Opticon--01012900000018.aspx
|
|
|
|
|
|
|
+ |
With this program you can download your data from OPL-9728 onto PC. Once you install the neto32 follow these steps:
|
|
|
|
|
|
|
+ |
On your OPL-9728 unit within the normal application:
|
|
|
+ |
:1. Select system menu-->Communicate-->Baudrate-->select 115200
|
|
|
+ |
:2. Select system menu-->Communicate-->Protocol-->select Neto Protocol
|
|
|
+ |
:3. Go to main screen and select "send date" and put the unit back into cradle.
|
|
|
|
|
|
|
+ |
From PC:
|
|
|
+ |
:1. open Neto32
|
|
|
+ |
:2.Tools--->options
|
|
|
+ |
:3.Select COM port (If RS232 is being used select COM1, otherwise go to control panel-->system-->Hardware-->Device Manager to find which COM port is assigned for you)
|
|
|
+ |
:4. choose 115200 for baudrate
|
|
|
+ |
:5. Parity "No"
|
|
|
+ |
:6. ByteSize "8 bits"
|
|
|
+ |
:7. Stop bit "1 bit"
|
|
|
+ |
:8.IrDa Device "None"
|
|
|
+ |
:9. Apply
|
|
|
+ |
:10. select Download and choose a location for your file.
|
|
|
+ |
:11. OK
|
|
|
+ |
:12. Protocol-->Start
|
|
|
+ |
Now data will be transfered into computer. You should also save your settings on Neto to avoid all these steps in future.
|
|
|
|
|
|