+ | ===First Time Setup=== | ||
+ | Follow the instructions below to get started with the OPL9723 on a Windows PC. | ||
+ | ====Installation==== | ||
+ | *To retrieve data from your OPL9723 you will need to download and install NetO32. If you are using a USB cradle then you will also need Opticon's USB drivers. Both of these are located in the [https://wiki.opticonusa.com/techsupport/en/OPL9723#Downloads Downloads section] of this page. You will only need to do this part once per computer. | ||
+ | ====Download Data==== | ||
+ | All of Opticon's Demo Applications for the OPL9723 support downloading of data through Opticon's proprietary protocol called NetO (Net-Oh). As with all communications there are two sides. In this case these are the terminal (the OPL9723) and the host (usually a PC). This section covers setting up and using such a communication channel. | ||
+ | =====Setting Up the Host===== | ||
+ | To use NetO communications on a PC you need an application called NetO32. This can be downloaded from the Downloads table at the bottom of this page. Simply run the installer after download is complete and follow the setup instructions here. | ||
+ | * Select 'Tools' > 'Options' | ||
+ | ** Choose RS232 from the menu at left | ||
+ | *** Choose the COM port for your cradle (COM 1 if using RS232, check Device Manager for USB ['Start' > 'Run' > 'devmgmt.msc' > click 'OK' and look under the 'Ports' section]) | ||
+ | *** Change Baudrate to 115200 | ||
+ | *** Change IrDA Device to 'None' | ||
+ | ** Choose 'Download' from the menu at left | ||
+ | *** Click the 'browse' folder icon at right to change the destination folder of the file once you have downloaded it. | ||
+ | *** Choose between 'Append', 'Overwrite', and 'Unique' to determine what happens when you download a data file but a file by that same name is already present. | ||
+ | ** Click 'OK' | ||
+ | * Select 'File' > 'Save As' | ||
+ | ** Choose a file name appropriate for you (such as your name or your company's name) to save the settings you just changed. | ||
+ | ** Now every time after this that you open NetO32 you must select 'File' > 'Open' and choose this file to load your settings. | ||
+ | * Select 'Protocol' > 'Start' | ||
+ | NetO32 is now in 'Polling' mode. Note that you should see the yellow light on the cradle blinking steadily. This means it will sit here indefinitely sending queries to the cradle and waiting for the right response to start a download. Multiple downloads can all be done without ever closing NetO32. When you are done using NetO32 simply select 'Protocol' > 'Stop' and NetO32 will discontinue polling mode. The application can then be closed. | ||
+ | =====Starting the Upload from your OPL9723===== | ||
+ | After NetO32 is in Polling mode (see above) follow these steps. First, of course, it is expected that you will have scanned some barcodes using the OPL9723. | ||
+ | * Select 'Send Data' from the main menu (use the arrow keys to move up and down and trigger (center key) to select an option. | ||
+ | * The screen that appears should say "Transmit Data via Cradle NETO Protocol -PRESS ANY KEY-'. Press any key. | ||
+ | * The unit will change to say 'Sending File Waiting NetO Connection ...'. At this point simply place the unit on the cradle. | ||
+ | * The OPL9723 will emit a series of short beeps and display 'File Was Sent. Delete Data File?'. Choose either YES or NO by pressing the appropriate arrow button below the display. The unit will now be back at the startup splash screen. | ||
+ | * Your Data File is now on the PC in the folder specified previously. | ||
+ | ====Alternative Transfer Modes==== | ||
+ | Although the NetO protocol will work in the vast majority of situations, the OPL9723 does support alternative protocols, including OSEComm and Raw ASCII. Depending on your needs and the level of support for NetO available within your platform, you may find either of these protocols to be more useful. | ||
+ | '''Enabling Raw ASCII Mode''' | ||
+ | Raw ASCII Mode will transfer the data file as a character stream over the COM port. You'll need software to listen on the other end, buffer the output, and process it into a text file. To enable Raw ASCII Mode on the OPL9723, first choose ''System Menu'' from the main menu. From here, select ''Communicate'', and in this submenu select ''Protocol''. To use Raw ASCII, make sure that ''No Protocol'' is checked. | ||
===Firmware Loading=== | ===Firmware Loading=== | ||
The OPL-9723 is basically a mini computer. As such it has an Operating System and runs Applications (one at a time, loding one application erases the previous one). The process for loading either the OS or an Application file is the same for both and so the instructions for either are combined here. Opticon always provides updates to the OS (see the Downloads table above). Opticon also provides free Applications for use on the OPL-9723 though it is also common for independent software vendors or resellers to develop their own software for use on the OPL-9723 (this is especially true if the company also provides PC side software). Applications made by Opticon are available at the Downloads table above (with the exception of software made custom by contract which is provided in other ways to the purchaser). Applications made by a third party must be retrieved from said party. | The OPL-9723 is basically a mini computer. As such it has an Operating System and runs Applications (one at a time, loding one application erases the previous one). The process for loading either the OS or an Application file is the same for both and so the instructions for either are combined here. Opticon always provides updates to the OS (see the Downloads table above). Opticon also provides free Applications for use on the OPL-9723 though it is also common for independent software vendors or resellers to develop their own software for use on the OPL-9723 (this is especially true if the company also provides PC side software). Applications made by Opticon are available at the Downloads table above (with the exception of software made custom by contract which is provided in other ways to the purchaser). Applications made by a third party must be retrieved from said party. |