Version Differences for IRU1300

(Page Creation and Dip Switch Settings charts)
Line 1:
    + The IRU-1300 charging and communication cradle is for use with Opticon's [[PHL1300|PHL-1300]] device.  
       
    + ==Dip Switch Settings==  
    + {|border="1"  
    + |-  
    + !DIP Switch!!Functions!!On!!Off!!Default  
    + |-  
    + |1||RS232 Connector||in use||not in use||ON  
    + |-  
    + |2||RS485 Terminator||in use||not in use||OFF  
    + |-  
    + |3||RS485 Terminator||in use||not in use||OFF  
    + |-  
    + |4||Baudrate*||--||--||OFF  
    + |-  
    + |5||Baudrate*||--||--||OFF  
    + |-  
    + |6||Baudrate*||--||--||ON  
    + |-  
    + |}  
    + :  
    + {|border="1"  
    + |-  
    + !Baudrate*!!SW 4!!SW 5!!SW 6  
    + |-  
    + |1200||OFF||OFF||OFF  
    + |-  
    + |2400||ON||OFF||OFF  
    + |-  
    + |4800||OFF||ON||OFF  
    + |-  
    + |9600||ON||ON||OFF  
    + |-  
    + |19200 (default)||OFF||OFF||ON  
    + |-  
    + |38400||ON||OFF||ON  
    + |-  
    + |115200||OFF||ON||ON  
    + |-  
    + |Auto (PC Controlled)||ON||ON||ON  
    + |-  
    + |}