+ | The IRU-1300 charging and communication cradle is for use with Opticon's [[PHL1300|PHL-1300]] device. | ||
+ | ==Dip Switch Settings== | ||
+ | {|border="1" | ||
+ | |- | ||
+ | !DIP Switch!!Functions!!On!!Off!!Default | ||
+ | |- | ||
+ | |1||RS232 Connector||in use||not in use||ON | ||
+ | |- | ||
+ | |2||RS485 Terminator||in use||not in use||OFF | ||
+ | |- | ||
+ | |3||RS485 Terminator||in use||not in use||OFF | ||
+ | |- | ||
+ | |4||Baudrate*||--||--||OFF | ||
+ | |- | ||
+ | |5||Baudrate*||--||--||OFF | ||
+ | |- | ||
+ | |6||Baudrate*||--||--||ON | ||
+ | |- | ||
+ | |} | ||
+ | : | ||
+ | {|border="1" | ||
+ | |- | ||
+ | !Baudrate*!!SW 4!!SW 5!!SW 6 | ||
+ | |- | ||
+ | |1200||OFF||OFF||OFF | ||
+ | |- | ||
+ | |2400||ON||OFF||OFF | ||
+ | |- | ||
+ | |4800||OFF||ON||OFF | ||
+ | |- | ||
+ | |9600||ON||ON||OFF | ||
+ | |- | ||
+ | |19200 (default)||OFF||OFF||ON | ||
+ | |- | ||
+ | |38400||ON||OFF||ON | ||
+ | |- | ||
+ | |115200||OFF||ON||ON | ||
+ | |- | ||
+ | |Auto (PC Controlled)||ON||ON||ON | ||
+ | |- | ||
+ | |} |