Version Differences for Composite Codes

Line 1:
    + Bar Code, Select Type: GS1 Composite  
       
    + GS1 Composite (formerly called UCC/EAN-128) uses the same code set as Code 128/GS1-128, except it does not allow function codes FNC2 through FNC4. FNC1 can be sent to the printer as the data string <SUB><SUB>1.  
       
    + Syntax  
       
    + c21[,m1][,m2][,m3][,m4][,m5][,m6]  
       
    + Parameters  
       
    + m1  
       
    + Sets the symbology version:  
       
    + m1 Version  
    + 0 UCC/EAN-128 with CC-C (default)  
    + 1 UCC/EAN-128 with CC-A or CC-B  
    + 2 EAN-13 with CC-A or CC-B  
    + 3 EAN-8 with CC-A or CC-B  
    + 4 UPC-A with CC-A or CC-B  
    + 5 UPC-E with CC-A or CC-B  
    + 6 GS1 Composite with CC-A or CC-B  
    + 7 GS1 Composite Truncated with CC-A or CC-B  
    + 8 GS1 Composite Stacked with CC-A or CC-B  
    + 9 GS1 Composite Stacked Omnidirectional with CC-A or CC-B  
    + 10 GS1 DataBar Limited with CC-A or CC-B  
    + 11 GS1 DataBar Expanded with CC-A or CC-B  
    + 12 GS1 DataBar Expanded Stacked with CC-A or CC-B  
    +  
       
    + The printer determines whether CC-A or CC-B will be used based on the amount of data sent to the 2D Composite Component.  
       
    + m2  
       
    + Height of the separator pattern row. Valid only when m1 is set to 0 or from 6 to 12.  
       
    + If the value for m2 is set too low, the height is changed to the smallest allowed value for the selected magnification.  
       
    + If the value for m2 is set too high, an "invalid bar code data" error occurs.  
       
    + Range: Between 1 time and 2 times the value set by Width of Line, Box, Bar, or Character Define. For example, if the width is set to 3, the range for m2 is 3 to 6.  
       
    + Default: 1  
       
    + m3  
       
    + Number of columns per row (or the number of segments per row if m1 = 12).  
       
    + Setting m1 and m3 to 0 selects the largest number of columns for the 2D bar code to fit within the 1D bar code (including its quiet zones).  
       
    + Range: 1 to 30  
       
    + Default: 0 if m1 = 0, or 4 if m1 = 12  
       
    + m4  
       
    + Enables display of space and parentheses ("(," ")") characters:  
       
    + m4 Description  
    + 0 Bar code does not include space or parentheses characters in the data, but displays these characters in the human readable interpretive field.  
    + 1 Bar code and human readable interpretive field include the space and parentheses characters.  
    +  
       
    + m5  
       
    + Height of each row in the 2D bar code.  
       
    + Default: 0 (height is 3 times the magnification value).  
       
    + m6  
       
    + Enables printing of the human readable interpretive field:  
       
    + m6 Description  
    + 0 Human readable interpretive field is not printed  
    + 1 Human readable interpretive field is printed  
    +  
       
    + The human readable interpretive field for the 2D Composite Component is displayed if Interpretive Field, Enable or Disable is set to 1.  
       
    + Notes  
       
    + The GS1 Composite symbology consists of an GS-128 linear component associated with an adjacent 2D Composite Component.  
       
    + The linear component encodes the primary identification so that it is readable by all scanning technologies and so that 2D imagers can use the linear component as a finder pattern for the adjacent 2D Composite Component. The linear components include these bar codes:  
       
    + UCC/EAN-128  
    + UPC-A  
    + EAN-8  
    + EAN-13  
    + GS1 DataBar family  
    + The 2D Composite Component encodes supplementary data, such as batch number or expiration date. There are three types of 2D Composite Components that are all based on the PDF417 symbology:  
       
    + CC-A is a structural variant of MicroPDF417.  
    + CC-B is a MicroPDF417 symbol.  
    + CC-C is a PDF417 symbol.  
    + 2D Composite Components encode characters from the ISO 646 code set..  
       
    + The data for the linear and 2D components is separated by the <HT> command with the data for the linear component sent first. For example, to print a Composite bar code with the linear component encoding 112233445566 and the 2D component encoding aabbccddeeff, the data is sent to the printer as 112233445566<HT>aabbccddeeff.  
       
    + This table lists all possible combinations of linear and 2D Composite components:  
       
    + Linear Component 2D Composite Component  
    + Maximum Data Length  
    + Bar Code Type Data Length CC-A CC-B CC-C  
    + GS-128 1-48 digits 56 digits  
    + 31 char 338 digits  
    + 196 char 2361 digits  
    + EAN-13 13 digits 56 digits  
    + 31 char 338 digits  
    + 196 char Not available  
    + EAN-8 8 digits 47 digits  
    + 26 char 219 digits  
    + 127 char Not available  
    + UPC-A 12 digits 56 digits  
    + 31 char 338 digits  
    + 196 char Not available  
    + UPC-E 8 digits 47 digits  
    + 26 char 96 digits  
    + 55 char Not available  
    + GS1 Composite, GS1 Composite Truncated 1-13 digits 56 digits  
    + 31 char 338 digits  
    + 196 char Not available  
    + GS1 Composite Stacked, GS1 Composite Stacked Omnidirectional 1-13 digits 47 digits  
    + 26 char 96 digits  
    + 55 char Not available  
    + GS1 DataBar Limited 1-13 digits 47 digits  
    + 26 char 219 digits  
    + 127 char Not available  
    + GS1 DataBar Expanded, GS1 DataBar Expanded Stacked 1-74 digits*  
    + 1-41 char* 56 digits  
    + 31 char 338 digits  
    + 196 char Not available  
    + Data lengths with an asterisk (*) indicate that the actual maximum amount of data depends on data content.  
       
    + See Also  
       
    + ISO 646 Subset Characters  
       
    + IPL Command Reference Manual, P/N